BENTLY3500/42M-PWA176449-02 - PROXIMITOR/SEISMIC MONITOR

BENTLY3500/42M-PWA176449-02 - PROXIMITOR/SEISMIC MONITOR

BENTLY PROXIMITOR/SEISMIC MONITOR

Origin: United States


Brand: Bentley


3500/42M-PWA176449-02 is a Proximitor/Seismic Monitor developed by Bently Nevada. It is a part of 3500/42M Proximitor/Seismic Monitor system. The Proximitor/Seismic Monitor takes input from proximity and seismic transducers, qualifies the signal to provide various vibrations and location measurements, and compares the conditioned signals to user-programmable alarms.

0.00
0.00
  

BENTLY PROXIMITOR/SEISMIC MONITOR

Origin: United States


Brand: Bentley


3500/42M-PWA176449-02 is a Proximitor/Seismic Monitor developed by Bently Nevada. It is a part of 3500/42M Proximitor/Seismic Monitor system. The Proximitor/Seismic Monitor takes input from proximity and seismic transducers, qualifies the signal to provide various vibrations and location measurements, and compares the conditioned signals to user-programmable alarms.

Product Introduction

Using the 3500 Rack Configuration Software, the user can program each channel of the 3500/42M to execute any of the

following functions:


Radial Vibration


Thrust Position


Differential Expansion


Eccentricity


REBAM


Acceleration


Velocity


Shaft Absolute


Circular Acceptance Region


3500/42M-PWA176449-02 Function


The main function of the 3500/42M monitor is to provide:


Machine protection through continual comparison of monitored parameters against defined alarm setpoints to generate alarms.


Important machine data for both operations and maintenance personnel.


Depending on the arrangement, each channel often conditions its input signal to yield various parameters known as "static values.

" The user has the option of configuring Alert setpoints for any active static value and Danger setpoints for any two active static values.


Alarm setpoints


The user can specify Alert levels for any value measured by the monitor and Danger setpoints for any two of the values measured

by the monitor using software setup. For each measured value, alarms can be set from 0 to 100 percent of full scale. The only exception

is when the fullscale range exceeds the transducer's range. In this instance, the transducer's range will limit the setpoint. Alarms

are accurate to within 0.13 percent of the desired value.

Many products have not been listed yet. Please contact us for more products If there is any inconsistency between the product

model and the displayed

picture, the model shall prevail. Please contact us for specific product pictures, and we will arrange for photos to be taken in the

warehouse for confirmation

Technical Team Service Hotline:0591-85299001





More Products