Bently Nevada3500/60133819-01 - RTD/TC TEMPERATURE I/O MODULE

Bently Nevada3500/60133819-01 - RTD/TC TEMPERATURE I/O MODULE

Bently NevadaRTD/TC TEMPERATURE I/O MODULE

Origin: United States


Brand: Bently Nevada


133819-01 is an RTD/TC Non-Isolated I/O Module with internal terminations developed by Bently Nevada. It is a part of 3500/60 & /61 Temperature Monitors. Both Resistance Temperature Detector (RTD) and Thermocouple (TC) temperature inputs are accepted by the modules for temperature monitoring, and they are compared to user-programmable alarm setpoints. The user can configure the RTD/TC non-isolated version to accept either TC or RTD, or a mixture of TC and RTD inputs. The TC isolated version provides 250 Vdc of channel-to-channel isolation to protect against external interference. The global industry standard and suggested material for all applications is platinum RTDs with 0.00385 alphas.

0.00
0.00
  

Bently NevadaRTD/TC TEMPERATURE I/O MODULE

Origin: United States


Brand: Bently Nevada


133819-01 is an RTD/TC Non-Isolated I/O Module with internal terminations developed by Bently Nevada. It is a part of 3500/60 & /61 Temperature Monitors. Both Resistance Temperature Detector (RTD) and Thermocouple (TC) temperature inputs are accepted by the modules for temperature monitoring, and they are compared to user-programmable alarm setpoints. The user can configure the RTD/TC non-isolated version to accept either TC or RTD, or a mixture of TC and RTD inputs. The TC isolated version provides 250 Vdc of channel-to-channel isolation to protect against external interference. The global industry standard and suggested material for all applications is platinum RTDs with 0.00385 alphas.

Product Introduction

133819-01 Features


The 3500/60 & 61 temperature monitoring modules have six channels and take both

Resistance Temperature Detector (RTD) and Thermocouple (TC) temperature inputs. These

inputs are conditionally compared to user-programmable alarm setpoints by the modules.


The 3500/60 and 3500/61 are functionally identical, with the exception that the 3500/61 has

recorder outputs on each of its six channels, but the 3500/60 does not. Using the 3500 Rack

Configuration Software, the user configures the modules to perform RTD or TC temperature

measurements.


RTD/TC non-isolated and TC isolated versions of several I/O modules are available. The

RTD/TC non-isolated version can be configured to take either TC or RTD inputs, or a

combination of TC and RTD inputs. To defend against external interference, the TC isolated

version provides 250 Vdc of channel-to-channel isolation.


Temperature monitors must be deployed in groups of three when utilized in a Triple Modular

Redundant (TMR) configuration. The system uses two methods of voting in this setup to

ensure correct operation and to avoid single-point failures.


Characteristics


RTD/TC Non-Isolated I/O


Six Channels of temperature monitoring


Temperature inputs : Resistance temperature detector (RTD) and thermocouple (TC)


Recorder Outputs for each channel (3500/61)


RTD/TC non-isolated or TC isolated versions


Dimensions (L x W x H) : 2.6cm x 11.2cm x 24.2cm


Weight : 0.46 Kg


Operating Temperature: -30 degrees Celsius to +65 degrees Celsius


Many products have not been listed yet. Please contact us for more products If there is any

inconsistency between the product modeland the displayedpicture,the model shall prevail. Please

contact us for specific product pictures, and we will arrange for photos to be taken in the warehouse

for confirmation

Technical Team Service Hotline:0591-85299001


More Products